6mm² Pure Copper Lug Cable with Ring Terminal — Crimped Battery & Solar Power Wire
6mm² Pure Copper Lug Cable with Ring Terminal Crimped Battery & Solar Power Wire
Couldn't load pickup availability
6mm² Pure Copper Lug Cable with Ring Terminal — Crimped Battery & Solar Power Wire
This 6mm² pure copper lug cable features a factory-crimped copper ring terminal on one or both ends, providing a low-resistance, vibration-proof connection for battery banks, solar systems, inverters, and grounding applications. Made from 99.9% pure copper stranded wire for maximum conductivity and flexibility.
Key Specifications
| Parameter | Value |
|---|---|
| Cross-Section | 6mm² (AWG 10 equivalent) |
| Conductor Material | 99.9% pure copper (stranded) |
| Terminal Type | Copper ring lug (crimped) |
| Current Capacity | Up to 50A (in free air) |
| Insulation Material | PVC or silicone (select variant) |
| Temperature Rating | -40°C to +105°C |
| Terminal Hole Size | M6 / M8 (select variant) |
Current Capacity by Cross-Section
| Cross-Section | AWG Equiv. | Max Current (Free Air) | Typical Use |
|---|---|---|---|
| 6mm² | AWG 10 | 50A | Solar panel, small inverter |
| 10mm² | AWG 8 | 70A | Battery to inverter (<1kW) |
| 16mm² | AWG 6 | 100A | Battery bank, 1–2kW inverter |
| 25mm² | AWG 4 | 130A | 2–3kW inverter, e-bike |
Why Choose Pure Copper Lug Cable?
- 99.9% Pure Copper — Lower resistance than CCA (copper-clad aluminum); less heat and voltage drop
- Factory Crimped Terminal — Hydraulic crimp ensures gas-tight connection; no corrosion at joint
- Flexible Stranded Wire — Easy routing in tight spaces; resistant to vibration fatigue
- Ring Terminal — Secure bolt-on connection; will not pull out under vibration
- PVC/Silicone Insulation — Oil, UV, and abrasion resistant for automotive and outdoor use
Typical Applications
- 12V/24V battery bank interconnect cables
- Solar panel to charge controller wiring
- Inverter to battery positive/negative cables
- Vehicle chassis grounding strap
- UPS and backup power system wiring
- Marine and RV electrical system wiring
FAQ
Q: What is the difference between pure copper and CCA (copper-clad aluminum) cable?
A: Pure copper has ~60% lower resistance than CCA at the same cross-section. CCA cables run hotter, have higher voltage drop, and are not suitable for high-current applications. Always use pure copper for battery and inverter connections.
Q: What terminal hole size do I need?
A: Match the terminal hole to your bolt size. M6 (6mm bolt) for most battery terminals and bus bars; M8 (8mm bolt) for larger inverter terminals. Check your equipment specifications before ordering.
Package Contents
- 1× 6mm² Pure Copper Lug Cable with Ring Terminal (length and terminal size per selected variant)