{"product_id":"fga25n120antd-n-channel-igbt-to247-1200v-25a-high-voltage-switching-2pack","title":"FGA25N120ANTD N-Channel IGBT — TO-247, 1200V 25A, High-Voltage Switching (2-Pack)","description":"\u003ch2\u003eFGA25N120ANTD N-Channel IGBT — TO-247, 1200V, 25A, High-Voltage Switching (2-Pack)\u003c\/h2\u003e\u003cp\u003eThe FGA25N120ANTD is a high-voltage N-channel IGBT in a TO-247 package, rated at 1200V collector-emitter voltage and 25A continuous collector current. Designed for high-voltage power conversion applications, it combines low saturation voltage with fast switching characteristics, making it suitable for induction heaters, solar inverters, UPS systems, and industrial motor drives operating from 400V AC mains or higher-voltage DC buses.\u003c\/p\u003e\u003ch3\u003eKey Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eTO-247 (through-hole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCollector-Emitter Voltage (VCES)\u003c\/td\u003e\n\u003ctd\u003e1200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Collector Current (IC)\u003c\/td\u003e\n\u003ctd\u003e25A (TC=25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate-Emitter Voltage (VGE)\u003c\/td\u003e\n\u003ctd\u003e±20V max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSaturation Voltage VCE(sat)\u003c\/td\u003e\n\u003ctd\u003e2.0V typ. (IC=25A, VGE=15V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Gate Charge (Qg)\u003c\/td\u003e\n\u003ctd\u003e~120nC typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-Off Energy (Eoff)\u003c\/td\u003e\n\u003ctd\u003eLow (optimized for switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55°C to +150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e2 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eFGA25N120ANTD vs HGTG30N60A4D — 1200V vs 600V IGBT\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eFGA25N120ANTD\u003c\/th\u003e\n\u003cth\u003eHGTG30N60A4D\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVCES\u003c\/td\u003e\n\u003ctd\u003e1200V\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC (continuous)\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003e400V AC mains, 3-phase inverters, solar\u003c\/td\u003e\n\u003ctd\u003eSingle-phase 230V, induction heaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial drives, solar inverter, UPS\u003c\/td\u003e\n\u003ctd\u003eZVS induction heater, resonant inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWhy Choose FGA25N120ANTD?\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1200V rating\u003c\/strong\u003e — essential for 400V AC three-phase mains applications (peak voltage ~565V + margin)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow VCE(sat) 2.0V\u003c\/strong\u003e — low conduction loss at 25A for efficient power conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTO-247 package\u003c\/strong\u003e — large tab for heatsink mounting, handles high power dissipation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage-controlled gate\u003c\/strong\u003e — driven by standard IGBT gate drivers (IR2110, HCPL-314J, 1EDC20I12AH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-pack value\u003c\/strong\u003e — one pair for half-bridge or push-pull topology testing\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatible With \/ Common Use Cases\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-phase solar inverter\u003c\/strong\u003e: 6× FGA25N120ANTD in 3-phase H-bridge for grid-tie inverter output stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial motor drive\u003c\/strong\u003e: 400V AC 3-phase motor drive inverter bridge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPS inverter\u003c\/strong\u003e: Single-phase or 3-phase UPS output stage from 400V DC bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInduction heater (high-voltage)\u003c\/strong\u003e: High-voltage ZVS or IGBT H-bridge induction heater from 220–400V supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWelding inverter\u003c\/strong\u003e: High-voltage IGBT H-bridge for inverter welder from 3-phase supply\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eQ: What gate driver should I use with FGA25N120ANTD?\u003c\/strong\u003e\u003cbr\u003eA: Use an isolated gate driver for 1200V applications — never use a non-isolated driver with 1200V IGBTs due to safety and noise isolation requirements. Recommended: HCPL-314J (Broadcom, isolated, 2.5A), 1EDC20I12AH (Infineon, isolated), or ACNW3190 (Broadcom). Drive with +15V \/ −15V gate voltage for full enhancement and fast turn-off. Use a 10–22Ω gate resistor.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: What heatsink is required for FGA25N120ANTD at full load?\u003c\/strong\u003e\u003cbr\u003eA: At 25A and VCE(sat)=2.0V, conduction loss is ~50W per device. Add switching losses for your frequency. For a 3-phase inverter at 10kHz, total losses per device may reach 80–100W. Use a heatsink with thermal resistance ≤0.3°C\/W with thermal paste and forced air cooling for full-load operation. Always calculate Tj = Ta + (Pd × Rth(j-c) + Pd × Rth(c-h)).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: Can FGA25N120ANTD replace GT50J325 or IRG4PC50W in an existing inverter?\u003c\/strong\u003e\u003cbr\u003eA: These are all 600–1200V IGBTs in TO-247. Verify VCES, IC, VCE(sat), switching times, and gate charge before substituting. FGA25N120ANTD (1200V\/25A) is generally compatible with other 1200V\/25A TO-247 IGBTs, but always confirm switching energy (Eon\/Eoff) matches your frequency requirements.\u003c\/p\u003e\u003ch3\u003ePackage Contents\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e2× FGA25N120ANTD N-Channel IGBT (TO-247)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Keszoox","offers":[{"title":"Default Title","offer_id":46991463153899,"sku":"\u003cnone\u003e","price":33.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0677\/1005\/8731\/files\/fga25n120-to247-igbt-power-transistor.webp?v=1761721031","url":"https:\/\/keszoox.com\/products\/fga25n120antd-n-channel-igbt-to247-1200v-25a-high-voltage-switching-2pack","provider":"Keszoox","version":"1.0","type":"link"}